Cfs sp wb is a versatile spray for curtain wall or edge of slab applications where.
Curtain wall detail metal deck floor line.
Our window wall system is designed to allow factory glazed window and door units to be installed between the floor slabs of multiple story buildings giving the appearance of curtain wall.
Detail title architectural abbreviations december 2008.
Model building codes require that the gap at the slab edge curtain wall interface be treated to maintain the same fire integrity as the floor ceiling.
Curtain wall detail glass curtain wall window detail roof detail cute night lights timber windows beautiful curtains aluminium doors beaded curtains.
Testing and listed.
When glass is used as the curtain wall an advantage is that natural light can penetrate deeper within the building.
Take a 100 x 100 ft.
Det detail df drinking fountain dia diameter diag diagonal diagram diag diagram diagonal diff difference or diffuser dim dimension dir direction disp dispenser dist distance div divide or division dl dead load doc document doug fir douglas fir doz dozen scale.
The steel structure is used to support the curtain wall at every floor slab.
Section 714 5 spandrel wall height and fire resistance requirements for curtain wall spandrels shall comply with section 705 8 5.
The life safety fire containment systems have been tested ul systems cw s 1001.
Dwg pdf fire resistive curtain wall joints comprehensive drawing 6 13 16 dwg pdf fire resistive interior wall joints comprehensive drawing 2 5 16 2 hr 2 hr top and bottom of wall joint for concrete over metal deck simplified drawing 2 29 16 2 hr 2 hr top and bottom of wall joint for flat deck simplified drawing 6 7 16.
The bronze tee bar is bolted to the steel angles.
1620 curtain wall system admd210en june 2019 features 1620 is an outside glazed captured curtain wall 1620 has a 2 50 8 sight line standard 6 152 4 or 7 1 2 190 5 depth systems standard infill options 1 4 6 4 and 1 25 4 thermally broken by means of a continuous 1 4 6 4 low conductance spacer.
The tee bar is plug welded to the continuous bronze mullions.
That narrow gap between your floor slab and façade is bigger than it looks.
Building with the usual 3 void.
Since the curtain wall is non structural it can be made of lightweight materials thereby reducing construction costs.
That s a tiny footprint but it adds up to 100 ft2 of open space for gas smoke and flames to rise from floor to floor.
Where section 705 8 5 does not require a fire resistance rated spandrel wall the requirements of sec tion 714 4 shall still apply to the intersection between the spandrel wall and the floor.